MODEL:HVU-60 Single Output Waterproof Power Supply |
Features:
High effectiency, High reliability, Low cost
Protections: Short circuit/Over load/Over
Waterproof grade: IP67
Natural cooling: 85¡æ high temperature
Working Frequncy: 65KHz
Suitable for LED lighten and moving sign
1 year warranty
Dimensions:180*69*45mm (L*W*H ) |

Shell code£ºH054 |
|
|
MODEL |
HVU-60-5 |
HVU-60-12 |
HVU-60-24 |
| OUTPUT |
DC VOLTAGE |
5¡À0.3V |
12¡À0.3V |
24¡À0.3V |
| Load Stability |
¡À2% |
¡À1% |
¡À0.5% |
| Enter-wire Stability |
¡À0.5% |
¡À0.5% |
¡À0.5% |
|
VOLTAGE TOLERANCE |
¡À2% |
¡À1% |
¡À1% |
|
RATED CURRENT |
10A |
5A |
2.5A |
|
CURRENT RANGE |
0-10A |
0-5A |
0-2.5A |
|
RATED POWER |
50W |
60W |
60W |
|
RIPPLE & NOISE |
80mVp-p |
100mVp-p |
100mVp-p |
|
SETUP,RISE,
TIME |
500ms¡¢30ms¡¢80ms /230VAC 1200ms¡¢30ms¡¢15ms /115VAC FULL LOAD |
| INPUT |
VOLTAGE RANGE |
88¡«264VAC 125¡«370VDC |
|
AC CURRENT |
0.5A/ 230 V 1A/115V |
|
EFFICIENCY |
78% |
82% |
84% |
|
INRUSH CURRENT |
COLD START 36A/230VAC |
|
LEAKAGE
CURRENT |
£¼2 mA/240VAC |
| PROTECTION |
OVER LOAD |
110%-180% |
| Protection£ºHiccup mode,recovers automatically after fault condition is removed |
| OVER VOLTAGE |
5.75-6.75V |
13.8-16.2V |
27.6-32.4V |
|
Protection£ºHiccup mode,recovers automatically after fault condition is removed |
| ENVIRONMENT |
Working Temp., Humidity |
-20¡æ¡«+70¡æ£»20%¡«90 %RH (Refer to output load derating curve) |
Storage Temp., Humidity |
-40¡æ¡«+85¡æ£»10%¡«95 %RH |
Vibration |
10¡«500Hz£¬2G 10min./1cycle£¬period for 60 min£¬each along X.Y.Z axes |
| SAFETY |
Withstand Voltage |
I/P-O/P:1.5KVAC I/P-FG: 1.5KVAC O/P-FG:0.5KVAC |
Isolation Resistance |
I/P-O/P, I/P-FG, O/P-FG: 100M Ohms / 500VDC |
| STANDARD |
Safety Standard |
EN61347-1 EN61347-2-13 IP67 |
EMC Standard |
EN55015 EN61547 EN 61000-3-2 EN61000-3-3 |
| OTHERS |
Weight |
|
Packing |
|
| NOTE |
1.All parameters NOT specially mentioned are measured at 230VAC input,
temperature.
2.Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted
47uf parallel capacitor.
3.Tolerance : includes set up tolerance, line regulation and load regulation. |