Products

       At first from material and material supplier after a rigorous selection process, we choice all right         components for each items, we have advanced workshop, quality control system, specially custom         design engineers. OEM/ODM is welcome and can be done in donghua.
MODEL:SKS-150 Single Output Switching Power Supply

Features:
High efficiency,high reliability
AC input range selected by switch
100% full load burn-in test
Protection: Short circuit/Over load/Over voltage
Cooling by free air convection
Fixed switching frequency at 25KHz
1 year warranty
Dimensions: 199*110*50mm(L*W*H)



casing No. : H005

MODEL

SKS-150-5

SKS-150-9

SKS-150-12

SKS-150-13.5

SKS-150-15

SKS-150-24

SKS-150-27

SKS-150-48

OUTPUT

DC Voltage

5V

9V

12V

13.5V

15V

24V

27V

48V

Voltage Tolerance

¡À2%

¡À1%

¡À1%

¡À1%

¡À1%

¡À1%

¡À1%

¡À1%

Rated Current

30A

16.7A

12.5A

11.2A

10A

6.5A

5.6A

3.2A

Current Range

0-30A

0-16.7A

0-12.5A

0-11.2A

0-10A

0-6.5A

0-5.6A

0-3.2A

Rated Power

150W

150.3W

150W

151.2W

150W

156W

151.2W

153.6W

Ripple & Noise

150mVp-p

180mVp-p

180mVp-p

180mVp-p

180mVp-p

240mVp-p

240mVp-p

240mVp-p

DC Adjustment Range

¡À10%

-12%,+15%

-12%,+10%

-12%,+11%

¡À10%

-12%,+16%

-12%,+11%

¡À10%

Setup, Rise, Hold Time

100ms,50ms,20ms at full load

INPUT

Voltage Range

88¡«132 VAC/176¡«264VAC 47~63Hz,selected by switch 248~370VDC

AC Current

3.2A/115 V 1.6A/ 230 V

Efficiency

78%

80%

82%

83%

84%

85%

86%

87%

Inrush Current

Cold start 35A/230VAC

Leakage Current

£¼3.5mA/240VAC

PROTECTION

Over Load

110%¡«160%

Protection type: Shut down o/p voltage, re-power on to recover

Over Voltage

115%~135%

Protection type: Shut down o/p voltage, re-power on to recover

ENVIRONMENT

Working Temp., Humidity

-10¡æ¡«+60¡æ£»20%¡«90 %RH

Storage Temp., Humidity

-20¡æ¡«+85¡æ£»10%¡«95 %RH

Vibration

10¡«500Hz£¬2G 10min./1cycle, period for 60min, each along X, Y, Z axes

SAFETY

Withstand Voltage

I/P-O/P:1.5KVAC I/P-O/P:1.5KVAC O/P-FG: 0.5KVAC

Isolation Resistance

I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC

STANDARD

Safety Standard

Design refer to UL1012, UL1950£¬TUV EN60950

EMC Standard

Design refer to EN55022£¬EN61000-3-2£¬-3£¬EN61000-4-2£¬3£¬4£¬5£¬6£¬8£¬11£»ENV50204£¬EN55024

OTHERS

Weight

0.8Kg

Packing

22pcs/18Kg/1.22CUFT

NOTE

  1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25¡æ of ambient temperature.
  2. Ripple & noise are measured at 20MHz of bandwidth by using a 12¡åtwisted pair-wire terminated with a 0.1¦Ì & 47¦Ì parallel capacitor.
  3. Tolerance: includes set up tolerance, line regulation and load regulation.
  4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.